Category
Lzck-55 Clamp Outdoor Waterproof Split Core Current Transformer
LZCK-55 Clamp Outdoor Waterproof Split Core Current Transformer LZCK series outdoor waterproof current transformers are
Basic Info
Model NO. | LZCK-55 |
Application | Electronic, Instrument |
Type | Current Transformer |
Phase | Single |
Operation Condition | Outdoor |
Usage | Protection, Measurement |
Winding Form | Single Layer & Tightly Wound Type |
Insulating Medium | Common Insulating Materials |
Installation | Active Type |
Magnetic Circuit Structure | Single Stage Type |
Voltage Transformation Principle | Electromagnetic Type |
Standards | IEC60044-1; IEC 61869-2; Ntc 2205; GB1208-2006; an |
Accuracy Class | 0.5s, 0.5%, 1%, 3% |
Range of Primary Rated Current | 100-1500A |
Rated Frequency | 50/60Hz |
Range of Rated Load | 10va |
Rated Secondary Current | 5A or 1A |
Aperture (mm) | 55 |
Weight (Kg) | 2 |
Ingress Protection | IP65 |
Environment | Outdoors or Indoors |
Transport Package | Standard Export Wooden Box |
Specification | 180mm*138mm*52mm |
Trademark | GFUVE |
Origin | Beijing, China |
Production Capacity | 10000pieces/Month |
Product Description
LZCK-55 Clamp Outdoor Waterproof Split Core Current TransformerLZCK series outdoor waterproof current transformers are applicable for AC power system 35kV and measurement of current of power supply equipment below 10KV also can be used for microcomputer protection. This type of current transformer employs imported silicon steel which with high permeability as magnetic material, has the characteristics of Small magnetic circuit loss and can be split, its semicircular core and secondary windings employ high quality epoxy resin vacuum, casting in plastic-case(ABS or PC) which is flame retardance anti-moisture, stable performance, no maintenance.
Parameters
Technical parameters | |
Standards | IEC60044-1; IEC 61869-2; NTC 2205; GB1208-2006; ANSI C57.13 |
Accuracy Class | 0.5S, 0.5%, 1%, 3% |
Range of primary rated current | 100-1500A |
Technical parameters - continued | |
Range of Rated load | ≤10VA |
Rated frequency | 50/60Hz |
Rated secondary current | 5A or 1A |
Rated short-me thermal current | 40kA, 1S |
Rated connuous thermal current | 150%I1n |
Secondary winding power frequency withstand voltage | 3kV, 1min |
Safety Factor Rang | (FS) <10 |
Output signal | 1A, 5A, 333mV, 1V or 5V(customized) |
Mechanical parameters | |
Aperture (mm) | Φ55 |
Dimensions (W×D×H) (mm) | 180×138×52 |
Weight (kg) | 2 |
Working condions | |
Operang temperature | -35°C to +65°C, average not exceeding +40°C |
Storage temperature | -40°C to +70°C |
Ingress Protecon | IP65 |
Environment | outdoors or indoors |
The Height of above sea level | 0- 3000m |
Condions | No existence of severely begrimed, erosive and radioacve gas in the air. Connuous working under the rated current is allowed. |
Model | Primary rated current | Rated load | Aperture (mm) | Descripon (mm) | Weight (kg) | Materia l | Water-proof |
LZCK-55 | 100-1500A | ≤10VA | φ55 | 180×138×52 | 2 | PC | IP65 |
LMCK185-10 | 300-3000A | ≤25VA | φ185 | 350×283×55 | 4.5 | PC | IP65 |
LZCK310-10 | 300-600A | ≤10VA | φ50 | φ50 x φ110 x 32 | 1 | Resin | silicon case (option) |
LZCK322-10 | 30-600A | ≤10VA | φ50 | φ50 x φ110 x 52 | 1.6 | Resin | silicon case (option) |
LZCK350-10 | 20-600A | ≤25VA | φ50 | φ50 x φ110 x 105 | 3.1 | Resin | silicon case (option) |
LZCG530-10 | 30-600A | ≤20VA | φ45 | φ45 x φ120 x 65 | 5 | Resin | silicon case (option) |