Lorawan Wireless Aluminum Steel Case Smart G2.5 Gas Meter
Basic Info
Model NO. | YW-TW |
Shell | Aluminum/Steel |
Power Supply Mode | Four AA Alkaline Dry Batteries |
Transport Packaging | Carton |
for | Civil/Industry |
HS Code | 9028101000 |
Production Capacity | 500 Pieces/Week |
Product Description
- Product Overview
- Functions and features
- Specifications & technical parameters
Parameter | G(J)2.5 |
Nominal flow(m³ /h) | 2.5 |
Maximum flow(m³ /h) | 4.0 |
Minimum flow(m³ /h) | 0.025 |
Working Pressures(kPa) | ≤30 |
Total Pressure Loss(Pa) | ≤250 |
Accuracy Level | 1.5 Class |
Basic Error Lines | qmin≤q< qt ±3.0% qt≤q≤qmax ±1.5% |
The tightness of the machine | It can last for 3 minutes without leakage under 1.5 times of the maximum working pressure |
Operating Ambient Temperature(ºC) | -25ºC~ +40ºC |
Inlet and Outlet Connector Threads | M30×2 |
Maximum Display Capacity of LCD(m³ ) | 999999 |
Maximum reading of base meter(m³ ) | 99999.999 |
Power supply mode | Four AA Alkaline dry batteries(AA LR6 1.5V) |
LoRaWAN frequency band (MHz) | IN864-865 |
Barrier-free meter reading distance | >3000m |
Compliant standards | GB/T 6968-2019,GB/T 3836-2021 |
- Display Description
•Consumption: cumulative consumption of gas meter
• Valve off/valve on: indication of valve switch status of gas meter • Lobat: When the battery voltage of the gas meter is insufficient, the LCD screen will prompt "Lobat" and close the valve. After replacing the battery, press the button to open the valve. • Fault code: Err005:forced valve closing Err006:strong magnetic interference Err008:valve fault Err010:pulse signal input abnormality Err023:pre-closing valve Err030:limited networking times in a single day- Overall dimension (unit: mm)
Parameter | W(mm) | W1(mm) | H(mm) | CC(mm) | L(mm) |
G2.5 | 152 | 62 | 227 | 130 | 172 |
- Installation and usage considerations
1. The installation shall be carried out in accordance with GB/T 3836.15-2017 Explosive Atmospheres - Part 15: Design, Selection and Installation of Electrical Installations. The installation of meters shall be carried out by professionals of the gas company for initial installation and commissioning.
2. This product has undergone explosion-proof treatment and shall not be changed at will.
3. The product shall not be collided or severely impacted during transportation, and shall be protected from rain and sand.
4. This product should be stored in a ventilated and dry place.
5. It is prohibited to detect leakage in case of open fire. When piloting fire, the air in the gas meter must be exhausted to prevent accidents.
6. When installing the battery, note that the side with the spring is the negative pole of the battery. The battery shall be replaced under the condition of good ventilation and no gas leakage.
7. Electrostatic hazard, so must be wiped with wrung wet cloth.
- Packaging, Transportation, and Storage
2.This product has undergone explosion-proof treatment and shall not be changed at will.
3.The product shall not be collided or severely impacted during transportation, and shall be protected from rain and sand.
4.This product should be stored in a ventilated and dry place.
5.It is prohibited to detect leakage in case of open fire. When piloting fire, the air in the gas meter must be exhausted to prevent accidents.
6.When installing the battery, note that the side with the spring is the negative pole of the battery. The battery shall be replaced under the condition of good ventilation and no gas leakage.
7.Electrostatic hazard, so must be wiped with wrung wet cloth.
- Note
2.Warning sign: Potential electrostatic charge is dangerous. During the normal use, maintenance and cleaning of gas meters, we should avoid the ignition hazard caused by electrostatic charges. Do not touch and wipe the equipment when it is used in explosive environment. If it is necessary to wipe and touch, it should be carried out in a well-ventilated, no gas leakage place. Wipe the shell with a wrung wet cloth. And it is strictly forbidden to wipe the shell with a dry cloth!
3.The battery must be replaced with the same type of battery under the condition of good ventilation and no gas leakage.