banner
Home / Products / Gas Meter
Products
Lorawan Wireless Aluminum Steel Case Smart G2.5 Gas Meter

Lorawan Wireless Aluminum Steel Case Smart G2.5 Gas Meter

Type YW-TW intelligent gas meter based on the IoT adopts LoRaWAN/CAT.1 wireless transmission technology. Automatically u
Basic Info
Model NO. YW-TW
Shell Aluminum/Steel
Power Supply Mode Four AA Alkaline Dry Batteries
Transport Packaging Carton
for Civil/Industry
HS Code 9028101000
Production Capacity 500 Pieces/Week
Product Description
  • Product Overview
Type YW-TW intelligent gas meter based on the IoT adopts LoRaWAN/CAT.1 wireless transmission technology. Automatically upload gas consumption data to the application platform to realize remote monitoring of gas meter usage status. It solves the problems of the traditional gas meter, such as the difficulty of over-reading the meter at home, the difficulty of paying the fee, and the inaccuracy of the supply and marketing difference.Explosion-proof sign ExibIIBT3 Gb. It is applicable to Zone 1 and Zone 2, containing IIA-IIB and T1-T3 explosive gas mixture.
  • Functions and features
1. Adopt LoRaWAN/CAT. 1 (optional) wireless technology. Effectively increase the anti-interference ability of the communication system and improve the accuracy of the received data; 2. The gas meter adopts the form of system prepayment. The valve switch of the gas meter is realized by the command from the system platform; 3. Timing (once a day) (settable) and key wake-up to transfer data to the platform. It improves the response speed of meter reading and reduces battery energy consumption; 4. When the voltage is low or abnormal, the LCD screen will automatically display the fault information, beep the alarm, and close the valve; 5. It has a built-in antenna. The transmission signal is stable and reliable; 6. The platform can remotely check the user's gas consumption, battery usage, and remotely control the valve switch of the gas meter; 7. It has the function of pulse signal open circuit self-inspection, which can effectively ensure the accuracy of gas meter measurement;
  • Specifications & technical parameters
ParameterG(J)2.5
Nominal flow(m³ /h)2.5
Maximum flow(m³ /h)4.0
Minimum flow(m³ /h)0.025
Working Pressures(kPa)≤30
Total Pressure Loss(Pa)≤250
Accuracy Level1.5 Class
Basic Error Linesqmin≤q< qt ±3.0% qt≤q≤qmax ±1.5%
The tightness of the machineIt can last for 3 minutes without leakage under 1.5 times of the maximum working pressure
Operating Ambient Temperature(ºC)-25ºC~ +40ºC
Inlet and Outlet Connector ThreadsM30×2
Maximum Display Capacity of LCD(m³ )999999
Maximum reading of base meter(m³ )99999.999
Power supply modeFour AA Alkaline dry batteries(AA LR6 1.5V)
LoRaWAN frequency band (MHz) IN864-865
Barrier-free meter reading distance>3000m
Compliant standardsGB/T 6968-2019,GB/T 3836-2021
  • Display Description

•Consumption: cumulative consumption of gas meter

• Valve off/valve on: indication of valve switch status of gas meter • Lobat: When the battery voltage of the gas meter is insufficient, the LCD screen will prompt "Lobat" and close the valve. After replacing the battery, press the button to open the valve. • Fault code: Err005:forced valve closing Err006:strong magnetic interference Err008:valve fault Err010:pulse signal input abnormality Err023:pre-closing valve Err030:limited networking times in a single day
  • Overall dimension (unit: mm)

Lorawan Wireless Aluminum Steel Case Smart G2.5 Gas Meter

ParameterW(mm)W1(mm)H(mm)CC(mm)L(mm)
G2.515262227130172
  • Installation and usage considerations

1. The installation shall be carried out in accordance with GB/T 3836.15-2017 Explosive Atmospheres - Part 15: Design, Selection and Installation of Electrical Installations. The installation of meters shall be carried out by professionals of the gas company for initial installation and commissioning.

2. This product has undergone explosion-proof treatment and shall not be changed at will.

3. The product shall not be collided or severely impacted during transportation, and shall be protected from rain and sand.

4. This product should be stored in a ventilated and dry place.

5. It is prohibited to detect leakage in case of open fire. When piloting fire, the air in the gas meter must be exhausted to prevent accidents.

6. When installing the battery, note that the side with the spring is the negative pole of the battery. The battery shall be replaced under the condition of good ventilation and no gas leakage.

7. Electrostatic hazard, so must be wiped with wrung wet cloth.

  • Packaging, Transportation, and Storage
1.The installation shall be carried out in accordance with GB/T 3836.15-2017 Explosive Atmospheres - Part 15: Design, Selection and Installation of Electrical Installations. The installation of meters shall be carried out by professionals of the gas company for initial installation and commissioning.
2.This product has undergone explosion-proof treatment and shall not be changed at will.
3.The product shall not be collided or severely impacted during transportation, and shall be protected from rain and sand.
4.This product should be stored in a ventilated and dry place.
5.It is prohibited to detect leakage in case of open fire. When piloting fire, the air in the gas meter must be exhausted to prevent accidents.
6.When installing the battery, note that the side with the spring is the negative pole of the battery. The battery shall be replaced under the condition of good ventilation and no gas leakage.
7.Electrostatic hazard, so must be wiped with wrung wet cloth.
  • Note
1.It is not allowed to replace components or structures that affect the explosion-proof performance at will, so as not to affect the explosion-proof performance.
2.Warning sign: Potential electrostatic charge is dangerous. During the normal use, maintenance and cleaning of gas meters, we should avoid the ignition hazard caused by electrostatic charges. Do not touch and wipe the equipment when it is used in explosive environment. If it is necessary to wipe and touch, it should be carried out in a well-ventilated, no gas leakage place. Wipe the shell with a wrung wet cloth. And it is strictly forbidden to wipe the shell with a dry cloth!
3.The battery must be replaced with the same type of battery under the condition of good ventilation and no gas leakage.

Lorawan Wireless Aluminum Steel Case Smart G2.5 Gas Meter