Model NO. GDYB-S3
Current range 250mA, 0.1A, 1A, 5A, 25A, 100A
Power supply 220V±10%, 50Hz (or 120V±10%, 60Hz)
Max. power consumption 300VA
Working temperature 20±5ºC
Relative humidity ≤85%
Delivery time 20-25 days
Transport Package Wooden Case
Specification ISO, SGS
Trademark HV Hipot
Origin Wuhan China
Product Description
Introduction

GDYB series Single Phase Energy Meter Test Bench is used to measure various kinds of single phase meters of 0.1% and below. It has good appearance, complete functions and excellent performance.

 

Specifications

* Special voltage range can be setup according to actual order.
Accuracy level0.1%
Output voltage3*100V/57.7V Y 3*100V ; 3*380V/220V Y 3*380V
Regulating range0-120% consecutively adjustable
Regulating accuracybetter than 0.01%
Current range25mA, 0.1A, 1A, 5A, 25A, 100A
Regulating range0-120% consecutively adjustable
Regulating accuracybetter than 0.01%
Min.output current1mA (accuracy: <5%)
Output power(voltage loop) GDYB-S3 3*50VA(current loop) GDYB-S3 3*150VA
Stability of output voltage, current and power:≤0.02%/120S PF=1 (Class 0.05)
Wave distortion of output voltage and current≤0.5%
Symmetry of three phasebetter than 120°+0.3°
Frequency range45Hz-65Hz regulating accuracy: 0.01 Hz
Phase shifting range-180.0°-180.0° regulating accuracy: 0.1°
Wave distortion of output voltage and current≤0.5%
Symmetry of three phasebetter than 120°+0.3°
Frequency range45Hz-65Hz regulating accuracy: 0.01 Hz
Phase shifting range-180.0°-180.0° regulating accuracy: 0.1°
Standard crystal oscillator stability≤10-7/s
Indicating instruments classVoltmeter and ammeter accuracy: level ±0.2%Phase meter accuracy: ±0.5°Frequency meter accuracy: ±0.01Hz

Specification of built-in 3-phase standard meterA. Voltage inputInput range(V): 40-480Input range(V): 60, 120, 240, 480Over-load ability(V): 600VInput load: ≤0.5mA(480V)B. Current inputInput range(A): 0.01-100100, 50, 25, 10, 5, 2.5, 1, 0.5, 0.25, 0.1, 0.05, 0.025Over-load ability(A): 150C. AccuracyAccuracy: class 0.05(0.1A-120A)Power measurement accuracyAccuracy of active power measurement: 0.05%/0.1%(pF≥0.5)Accuracy of reactive power measurement: 0.1%, 0.2%(pF≥0.5)Power energy measurement accuracyAccuracy of active power energy measurement: 0.05%, 0.1%(pF≥0.5)Accuracy of reactive power energy measurement: 0.1%, 0.2%(pF≥0.5)With voltage short-circuit, current open-circuit protection, over-load protection.2-21times harmonic test, voltage interrupt and drop test, harmonic amplitude can be adjustable.Maximum meters for test: 3Power supply: 220V±10%, 50Hz (or 120V±10%, 60Hz)Maximum power consumption: 300VAWorking temperature: 20±5ºC relative humidity: ≤85%